Resumen
Este informe analiza la conveniencia de incorporar una interfaz web embebida a un dispositivo desarrollado en INTA – IPAF Pampeano para la medición local de temperatura. El equipo actual utiliza un LCD y tres sensores de temperatura, funciona conectado a la red eléctrica y está instalado en un espacio sin conectividad Wi-Fi, lo que obliga a realizar controles visuales periódicos y registrar los valores manualmente.
El dispositivo fue utilizado
[ver mas...]
This report analyzes the feasibility of incorporating an embedded web interface into a device developed at INTA – IPAF Pampeano for local temperature measurement. The current device uses an LCD and three temperature sensors, operates connected to the electrical grid, and is installed in a space without Wi-Fi connectivity, requiring periodic visual checks and manual recording of values. The device was initially used in an experimental prototype, although
[ver mas...]
| dc.contributor.author | Franceschi, Luis Alberto | |
| dc.coverage.spatial | Pampa .......... (general region) (World, South America, Argentina) | es_AR |
| dc.coverage.spatial | 1112114 | |
| dc.date.accessioned | 2026-01-06T11:28:41Z | |
| dc.date.available | 2026-01-06T11:28:41Z | |
| dc.date.issued | 2025-12 | |
| dc.identifier.uri | http://hdl.handle.net/20.500.12123/24889 | |
| dc.description.abstract | Este informe analiza la conveniencia de incorporar una interfaz web embebida a un dispositivo desarrollado en INTA – IPAF Pampeano para la medición local de temperatura. El equipo actual utiliza un LCD y tres sensores de temperatura, funciona conectado a la red eléctrica y está instalado en un espacio sin conectividad Wi-Fi, lo que obliga a realizar controles visuales periódicos y registrar los valores manualmente. El dispositivo fue utilizado inicialmente en un prototipo experimental, aunque su diseño es genérico y aplicable a cualquier proyecto que requiera mediciones locales sin conectividad externa. Se propone evaluar la incorporación de una interfaz web servida por el propio ESP32, generando un punto de acceso Wi-Fi local para consulta mediante un teléfono móvil. La interfaz mostraría las mismas lecturas del LCD y permitiría acceder a archivos con registros históricos almacenados en memoria. En este informe se analizan requerimientos, ventajas y limitaciones de esta mejora. | spa |
| dc.description.abstract | This report analyzes the feasibility of incorporating an embedded web interface into a device developed at INTA – IPAF Pampeano for local temperature measurement. The current device uses an LCD and three temperature sensors, operates connected to the electrical grid, and is installed in a space without Wi-Fi connectivity, requiring periodic visual checks and manual recording of values. The device was initially used in an experimental prototype, although its design is generic and applicable to any project requiring local measurements without external connectivity. The proposal is to evaluate the incorporation of a web interface served by the ESP32 itself, generating a local Wi-Fi access point for consultation via a mobile phone. The interface would display the same LCD readings and allow access to files with historical records stored in memory. This report analyzes the requirements, advantages, and limitations of this improvement. | eng |
| dc.format | application/pdf | es_AR |
| dc.language.iso | spa | es_AR |
| dc.publisher | IPAF Región Pampeana, INTA | es_AR |
| dc.rights | info:eu-repo/semantics/openAccess | es_AR |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/4.0/ | es_AR |
| dc.subject | Temperature Measurement | eng |
| dc.subject | Termometría | es_AR |
| dc.subject | Monitoring and Evaluation | eng |
| dc.subject | Seguimiento y Evaluación | es_AR |
| dc.subject | Interface Phenomena | eng |
| dc.subject | Interfase | es_AR |
| dc.subject | E-learning | eng |
| dc.subject | Aprendizaje Electrónico | es_AR |
| dc.subject.other | Web Interface | eng |
| dc.subject.other | Interfaz Web | es_AR |
| dc.subject.other | Región Pampeana | es_AR |
| dc.title | Evaluación de la incorporación de una interfaz web a un dispositivo de medición de temperatura utilizado en INTA – IPAF Pampeano | es_AR |
| dc.type | info:ar-repo/semantics/informe técnico | es_AR |
| dc.type | info:eu-repo/semantics/report | es_AR |
| dc.type | info:eu-repo/semantics/publishedVersion | es_AR |
| dc.rights.license | Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) | es_AR |
| dc.description.origen | Instituto de Investigación y Desarrollo Tecnológico para la Agricultura Familiar Región Pampeana (IPAF Región Pampeana) | es_AR |
| dc.description.fil | Fil: Franceschi, Luis Alberto. Instituto Nacional de Tecnología Agropecuaria (INTA). Instituto de Investigación y Desarrollo Tecnológico para la Agricultura Familiar Región Pampeana (IPAF Región Pampeana); Argentina. | es_AR |
| dc.subtype | tecnico |