View Item
- xmlui.general.dspace_homeCentros Regionales y EEAsCentro Regional Entre RíosEEA ParanáTesisxmlui.ArtifactBrowser.ItemViewer.trail
Desgaste acelerado en boquillas de abanico plano con inducción de aire. Su efecto sobre el caudal y la exoderiva
Abstract
La pulverización del caldo asperjado contenido en un circuito hidráulico sometido a presión a través de boquillas convencionales, modifica la cantidad y calidad del caldo asperjado. Con el objetivo de evaluar las prestaciones de las boquillas abanico plano con inducción de aire luego de ser sometidas al desgaste acelerado se establecieron una serie de ensayos en banco de desgaste y túnel de viento. Como abrasivo se utilizó oxido de aluminio al 2% en banco
[ver mas...]
La pulverización del caldo asperjado contenido en un circuito hidráulico sometido a presión a través de boquillas convencionales, modifica la cantidad y calidad del caldo asperjado. Con el objetivo de evaluar las prestaciones de las boquillas abanico plano con inducción de aire luego de ser sometidas al desgaste acelerado se establecieron una serie de ensayos en banco de desgaste y túnel de viento. Como abrasivo se utilizó oxido de aluminio al 2% en banco de desgaste construido bajo la norma ISO 5682-1. Las boquillas evaluadas fueron Airmix, Guardian AI ambas con inserto de polímero (800 y 1,200 ml min -1) y Teejet con inserto de polímero y acero inoxidable (790 y 1180 ml min -1). Se evaluaron los caudales erogados por las boquillas en las distintas etapas del desgaste (0 min, 4 min, 25 min, 1h 30 min y 7h 30 min), luego se midieron los caudales erogados bajo la acción del aire de frente generado en túnel de viento y por diferencia se obtuvo el volumen derivado. El diseño de las boquillas juega un rol decisivo en el control de deriva. Los caudales erogados acusaron efecto del desgaste, a pesar de no superar en ningún momento el caudal nominal en ambos caudales de boquillas, solo en las boquillas de menor sección se vio alterado el volumen derivado.
[Cerrar]
Spraying the liquid in a hydraulic circuit under pressure through conventional nozzles , modifies the quantity and quality of the sprayed. In order to evaluate the performance of flat fan nozzle with air induction after being subjected to accelerated wear a series of tests were established in bank wear and wind tunnel. As aluminum oxide abrasive 2% is used in wear bank built under ISO 5682-1. Airmix and Guardian AI nozzles were tested, both with polymer
[ver mas...]
Spraying the liquid in a hydraulic circuit under pressure through conventional nozzles , modifies the quantity and quality of the sprayed. In order to evaluate the performance of flat fan nozzle with air induction after being subjected to accelerated wear a series of tests were established in bank wear and wind tunnel. As aluminum oxide abrasive 2% is used in wear bank built under ISO 5682-1. Airmix and Guardian AI nozzles were tested, both with polymer insert (800 and 1,200 ml min -1) and Teejet with polymer and stainless steel insert (790 and 1180 ml min-1). Flows incurred by the nozzles at various stages of wear (0 min, 4 min, 25 min, 1h 30 min and 7h 30 min) were evaluated, then flows incurred under the action of the front air were measured generated by wind tunnel Unlike and the volume derivative is obtained.
The nozzle design plays a decisive role in controlling drift. The incurred
flows accused effect of wear, although not at any time exceed the nominal flow
in both flow nozzle, only the nozzles of smaller section was altered volume
derivative.
[Cerrar]
Author
Director de Tesis
Descripción
Tesis para optar al grado de Magister Scientiae en Mecanización Agraria, de la Universidad Nacional de La Plata, en 2019