Mostrar el registro sencillo del ítem

resumen

Resumen
Since their development, AFLP (amplified fragment length polymorphism) markers have been used for a wide variety of analyses and, up to this day, are considered highly informative, robust, and reproducible molecular markers. Originally, the visualization of the amplified fragments was done in polyacrylamide gels, followed by silver staining or by developing in an X-ray plate, when radioactivity is used. In the last 14 years, capillary electrophoresis of [ver mas...]
dc.contributor.authorCara, Nicolás
dc.contributor.authorMarfil, Carlos Federico
dc.contributor.authorGarcia Lampasona, Sandra Claudia
dc.contributor.authorMasuelli, Ricardo Williams
dc.date.accessioned2018-06-21T12:33:45Z
dc.date.available2018-06-21T12:33:45Z
dc.date.issued2014-06
dc.identifier.issn1916-2790
dc.identifier.issn1916-2804
dc.identifier.otherhttps://doi.org/10.1139/cjb-2014-0047
dc.identifier.urihttp://hdl.handle.net/20.500.12123/2664
dc.identifier.urihttp://www.nrcresearchpress.com/doi/10.1139/cjb-2014-0047#.WyuX_jdKjcs
dc.description.abstractSince their development, AFLP (amplified fragment length polymorphism) markers have been used for a wide variety of analyses and, up to this day, are considered highly informative, robust, and reproducible molecular markers. Originally, the visualization of the amplified fragments was done in polyacrylamide gels, followed by silver staining or by developing in an X-ray plate, when radioactivity is used. In the last 14 years, capillary electrophoresis of fluorescently labeled fragments has been gradually replacing gel-based systems. However, the latter continue to be better for isolating and cloning AFLP fragments. In this report, we compare the results obtained by capillary electrophoresis with those from silver staining. We found that if fluorescence-labeled amplification products are loaded in a polyacrylamide gel, duplicated bands (doublets) are seen. This phenomenon is probably due to a delay in the migration of the strand that carries the fluorophore. Therefore, we recommend a minimum separation of 4 bp from the nearest fragment to the target fragment for its unambiguous identification and isolation. If this requirement is not fulfilled, an alternative is to make new amplifications using the same primer combination, but with unlabeled primers.eng
dc.formatapplication/pdfes_AR
dc.language.isoenges_AR
dc.rightsinfo:eu-repo/semantics/restrictedAccesses_AR
dc.sourceBotany 92 (8) : 607-610 (2014)es_AR
dc.subjectMarcadores Genéticoses_AR
dc.subjectGenetic Markerseng
dc.subjectPolimorfismo de Longitud de Fragmentos Amplificadoses_AR
dc.subjectAmplified Fragment Length Polymorphismeng
dc.subjectPlantases_AR
dc.subjectPlantseng
dc.subjectElectrofóresis Gel Poliacrilamidaes_AR
dc.subjectPolyacrylamide Gel Electrophoresiseng
dc.subject.otherAFLPes_AR
dc.subject.otherMarcadores Moleculareses_AR
dc.titleComparison of two detection systems to reveal AFLP markers in plantses_AR
dc.typeinfo:ar-repo/semantics/artículoes_AR
dc.typeinfo:eu-repo/semantics/articlees_AR
dc.typeinfo:eu-repo/semantics/publishedVersiones_AR
dc.description.origenEEA La Consultaes_AR
dc.description.filFil: Cara, Nicolás. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza. Instituto de Biología Agrícola de Mendoza. Universidad Nacional de Cuyo. Facultad de Ciencias Agrarias. Instituto de Biología Agrícola de Mendoza; Argentinaes_AR
dc.description.filFil: Marfil, Carlos Fedrico. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza. Instituto de Biología Agrícola de Mendoza. Universidad Nacional de Cuyo. Facultad de Ciencias Agrarias. Instituto de Biología Agrícola de Mendoza; Argentinaes_AR
dc.description.filFil: Garcia Lampasona, Sandra Claudia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza. Instituto de Biología Agrícola de Mendoza. Universidad Nacional de Cuyo. Facultad de Ciencias Agrarias. Instituto de Biología Agrícola de Mendoza; Argentina. Instituto Nacional de Tecnología Agropecuaria (INTA). Estación Experimental Agropecuaria La Consulta; Argentinaes_AR
dc.description.filFil: Masuelli, Ricardo Williams. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza. Instituto de Biología Agrícola de Mendoza. Universidad Nacional de Cuyo. Facultad de Ciencias Agrarias. Instituto de Biología Agrícola de Mendoza; Argentina. Instituto Nacional de Tecnología Agropecuaria (INTA). Estación Experimental Agropecuaria La Consulta; Argentinaes_AR
dc.subtypecientifico